Extended System Commands
E-Class DPL Programmer’s Manual 43
F Font Attributes
This command extends the text presentation capabilities (bold and/or italic) of scalable fonts. The
selected font attribute remains in effect, modifying the font attributes of subsequent DPL text records
within the label format, until the command is turned off or until the label format is terminated with
the ‘E’ ‘s’ or ‘X’ command. All label formats begin by default with both font attributes disabled.
Note: These commands are only valid for “scalable” fonts, such as downloaded TrueType
scalable fonts (or optional Internal Font 9, S00 and S01 with appropriate optional font sets).
Syntax:
Fax
Where:
a
- Is font attribute B - Bold, I - Italic
x
- Is minus ‘-’ disable, plus ‘+’ enable.
Sample:
<STX>L
D11
1911SA001000080P015P015ABCDEF
FB+
1911SA001500080P015P015ABCDEF
FB-
FI+
1911SA002000080P015P015ABCDEF
FI-
1911SA002500080P018P018E-CLASS
E
The sample illustrated above will print one label, shown right. Note
that to print the sample, a scalable font with ID ‘A0’ was downloaded
to the printer prior to sending the label format datastream.