Datamax E4203 User Manual Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 176
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
Extended System Commands
30 E-Class DPL Programmer’s Manual
Syntax:
<STX>Kcaa
1
val
1
[;aa
I
val
I
][;aa
n
val
n
]<CR>
Where:
aa
1,
aa
I
,aa
n
- Are two letter parameter names
val
1,
val
I,
val
n
- Are parameter values, with ranges appropriate for
the associated parameter
Sample:
<STX>KcPA120;CL600;STC<CR>
The sample sets the Present Adjust to 120 dots, the Continuous Label Length to 6 inches, and the
Media Sensor Type to Continuous.
The following table summarizes the different Set Configuration Command parameters. Descriptions
of these parameters can be found by referencing the Command Equivalent. Where no equivalent is
given, Unique parameters descriptions are given below.
Parameter
Name
Parameter
Pneumonic
Value
Range
Units /
Interpretation
Setup
Menu
Item
Command
Equivalent
Continuous Label Length CL 0 – 9999 1/100 in. 10 <STX>c
Configuration Query QQQ none none N/A N/A
Control Codes CC S, 1, 2 Standard, Alternate, Alternate-2 9 <STX>KD
Cutter Equip CE Y, N Enabled, Disabled 4 <STX>KD,
<STX>V
Internal Module A IM 0 – 128 4KB 17 <STX>KM
Label Alignment LA Y, N, A Enabled, Disabled, Automatic 18 N/A
Label Alignment Length AL 000 – 999 1/100 inch 19 N/A
Label Width LW 75 - head width 1/100 inch 15 <STX>KM
No Paper Min (OOS) TN 0–16 .1 Volt DC 11 N/A
No Paper Min Reflective RN 0–16 .1 Volt DC 11 N/A
Print Method MT D, T Direct, Thermal Transfer 1 <STX>KD
Present Adjust PA 0 – 255 Dots 6 N/A
Present Sensor Enable PS Y, N Enabled, Disabled 3 <STX>KD,
<STX>V
Scalable Cache SC 0 – 128 4KB(0=disabled) 16 <STX>KS
Sensor Type ST G, C, R Gap (Edge), Continuous,
Reflective
2 <STX>e,
<STX>r,
<STX>KD
Serial Port Configuration SP A See details below 7, 8 <STX>KD
SOP Adjust SA 0 – 255 Dots 5 N/A
Stop Location SL H, P, C, T, N Host,Peel,Cut,Cover,None 20 N/A
TOF Bias TB 0–50 .1 Volt DC 14 N/A
TOF Bias Reflective RB 0–50 .1 Volt DC 14 N/A
TOF Delta TD 0–50 .1 Volt DC 13 N/A
TOF Delta Reflective RD 0–50 .1 Volt DC 13 N/A
TOF Gain TG 0–15 .1 Volt DC 12 N/A
TOF Gain Reflective RG 0–15 .1 Volt DC 12 N/A
Table 5-2: Set Configuration Commands
Configuration Query This command causes the printer to respond with the current
configuration settings. The <STX>Kc response command stream format is sent to the host
Page view 39