Datamax H-4606X Operator's Manual Page 97

  • Download
  • Add to my manuals
  • Print
  • Page
    / 186
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 96
H-Class 87
Advanced Entry Calibration (continued)
Step
Action Displayed Message Comment
R
Press and hold the FEED
Key until at least one label
has been output.
CALIBRATION COMPLETE
Followed by...
READY
The printer is ready for
use.
;
If the calibration
attempt fails, try
desensitizing the
sensor as follows:
Re-enter the
ADVANCED MENU. Go
to MEDIA SETTINGS /
SENSOR
CALIBRATION /
ADVANCED ENTRY /
TRAN (or REFL)
SENSOR GAIN and
lower the
corresponding GAIN
SETTING by one. Exit
the menu and save
your changes. Test
your media at the
new setting. If
necessary, repeat
until a usable Gain
Setting is obtained.